Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Is there a control board, PCB in the panel that could have problems? Still no luck. Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? If you are not sure if your timer is working or not you will first need to know if its even operational. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Thank you for choosing Intermatic! You can check these easily by removing them and inspecting them for damage. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. AJH Trade Group also participate in other affiliate programs. The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. Okay, so lets move on to the Intermatic Pool Timer troubleshooting and figure out why your timer is not working. There are many reasons why your pool timer may not be working. The trippers push on a tab on the on/off switch. I unscrewed the clip and put it back on and its still doing the same thing. Also be sure that the front dial is engaged with the gear located behind the dial. Pool pump comes on fine with the on dog, but wont turn off. I guess if they look the same as before maybe the dial is warped? Please let me know if you find the solution! You will want to make sure the manual switch under the timer wheel is pushed to the on position. It randomly loses the time that it is set to. Your timer is on a 24-hour cycle. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. Ive got the opposite problem than a lot of people. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Check that dial is not warped. There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. Not sure if you still answer these but I have a weird one for you. Articles and resources for swimming pool owners and DIYers. Line is incoming, Load goes to the pump. Hi, new timer out of the box, 200V. My pool pump and skimmer are on two different motors. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. It would not reset itself and could not get power back to the timer. 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? Sound right? Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . What do you suggest to do to get the cover up and the pillows back into position. The most common pool timer used for inground pool pumps is the Intermatic time clock. 3 Baths. Close. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. No luck. When I put the new one on, the trippers do not work. If you use our referring links, it costs you nothing extra. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. "name": "Davy Merino",
If I manually flip the switch nothing happens. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. The A terminal is not normally used, unless you have a 3 wire service. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. If your pool pump timer is beyond repair, call a professional to replace it. GFCI breakers trip at a very low threshold, doesnt take much. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. See the point above if it is. Any guidance on how to fix this? by Intermatic Technical Support | Jul 25, 2022 Helpful? The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Watch these tips and tricks before replacing it. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. "logo": {
Keeping a pool operational is expensive enough anyway, so every saving you can make helps. See the next section in this article for that. What was the fix?? Now try to jiggle it on and off. But of the timer itself is bad you will need a licensed electrician to change the timer for you. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. Pool Timer Clock Parts and Trippers Turn in either direction and align the exact time-of-day on . View more property details, sales history and Zestimate data on Zillow. . The trippers will "trip" the analog clock to turn on and off automatically at the set times. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. "height": "219",
If not, that sounds like a weak/bad motor. I have a white, red, and black wire coming from the power source. The timer appears to be working fine (keeps time). I can manually turn it on with the lever at the bottom. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. I manually turn it on timer is running, it will trip pump OFF. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Pool co says T104 timer needs replacement and filter cartridge. When you flip the switch does it separate and reconnect the tabs? What happened? A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. Ordered new ones. Back when I was a young technician I was taught to always look for the easy things and use all my senses. do i need to do something different? Death By Audio / Levitation Speed Tripper Feedback Phasing Delay I have an intermatic timer thats 2 years young. Any suggestions on how to troubleshoot? You can have as many ON an OFF trippes as you want. Everythings OK now, unit works just fine. Hello Davy, Terry here again. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). 1. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. "dateModified": "1/10/2020",
This div height required for enabling the sticky sidebar. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Also known as an RCD (residual current device) in Australia and the UK. Intermatic Mechanical Timer Mechanism Only, 40 Amp, 220 Volt, DPST, 24 what causes timer on/off pins to bend and how can i prevent timer pins from bending. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! the timer was directly plugged into a gfci and the pump directly into the timer. I had to order new trippers as mine have been straightened too many times. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. by pool co. , so wondered about the cost. With the breakers turned off, remove the mechanism from the box. After a power failure the timer clock can start up backwards, mine has done this several times. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Could I send you a picture of my setup? "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. Terminal A (farthest to the left side) is not connected to anything. Stupid third question, but does the ON tripper say ON? Grab it, pull it towards you, move it around then place it back down. Reddit - Dive into anything If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. "author": {
Phil. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Can I spray the timer while there is electricity going in the timer box? If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Open following links to identify timer and then add a comment. Thanks for your help! TORK Repair Questions & Solutions, Tips & Guides - Fixya Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. My timer clock does not run and the manual on off switch does not turn off the pump motor.
If I manually flip the switch nothing happens. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. The A terminal is not normally used, unless you have a 3 wire service. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. If your pool pump timer is beyond repair, call a professional to replace it. GFCI breakers trip at a very low threshold, doesnt take much. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. See the point above if it is. Any guidance on how to fix this? by Intermatic Technical Support | Jul 25, 2022 Helpful? The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Watch these tips and tricks before replacing it. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. "logo": {
Keeping a pool operational is expensive enough anyway, so every saving you can make helps. See the next section in this article for that. What was the fix?? Now try to jiggle it on and off. But of the timer itself is bad you will need a licensed electrician to change the timer for you. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. Pool Timer Clock Parts and Trippers Turn in either direction and align the exact time-of-day on . View more property details, sales history and Zestimate data on Zillow. . The trippers will "trip" the analog clock to turn on and off automatically at the set times. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. "height": "219",
If not, that sounds like a weak/bad motor. I have a white, red, and black wire coming from the power source. The timer appears to be working fine (keeps time). I can manually turn it on with the lever at the bottom. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. I manually turn it on timer is running, it will trip pump OFF. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Pool co says T104 timer needs replacement and filter cartridge. When you flip the switch does it separate and reconnect the tabs? What happened? A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. Ordered new ones. Back when I was a young technician I was taught to always look for the easy things and use all my senses. do i need to do something different? Death By Audio / Levitation Speed Tripper Feedback Phasing Delay I have an intermatic timer thats 2 years young. Any suggestions on how to troubleshoot? You can have as many ON an OFF trippes as you want. Everythings OK now, unit works just fine. Hello Davy, Terry here again. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). 1. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. "dateModified": "1/10/2020",
This div height required for enabling the sticky sidebar. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Also known as an RCD (residual current device) in Australia and the UK. Intermatic Mechanical Timer Mechanism Only, 40 Amp, 220 Volt, DPST, 24 what causes timer on/off pins to bend and how can i prevent timer pins from bending. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! the timer was directly plugged into a gfci and the pump directly into the timer. I had to order new trippers as mine have been straightened too many times. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. by pool co. , so wondered about the cost. With the breakers turned off, remove the mechanism from the box. After a power failure the timer clock can start up backwards, mine has done this several times. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Could I send you a picture of my setup? "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. Terminal A (farthest to the left side) is not connected to anything. Stupid third question, but does the ON tripper say ON? Grab it, pull it towards you, move it around then place it back down. Reddit - Dive into anything If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. "author": {
Phil. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Can I spray the timer while there is electricity going in the timer box? If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Open following links to identify timer and then add a comment. Thanks for your help! TORK Repair Questions & Solutions, Tips & Guides - Fixya Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. My timer clock does not run and the manual on off switch does not turn off the pump motor.